The Vendor is required to provide projectile data acquisition system requirements:
• 1-inch diameter or less, 3-inch length or less, cylindrical profile
• Single channel, at least 800 kS/s with 12-bit resolution
• At least 0.5 seconds of recording time
• Programmable pre/post-trigger
• Immediate or externally armed
• Programmable countdown timer with internal triggering
• Low-pass filtering (e.g. 6-pole Butterworth at 160 kHz cut-off frequency)
• Programmable gain
• Internal power source
• 150 gram weight or less
• 30 kG @ 10 msec acceleration resilience or better
• Sensor pass through to interface with medtherm Type E thermocouple