The vendor is required to provide vehicle presence detection system that uses active radar technology to provide reliable detection under a wide variety of environmental and lighting conditions.
- The system will also include a visual monitoring component to allow city staff to remotely observe and verify traffic conditions in real time.
- This new system is intended to overcome the limitations of visual-only detection, particularly in challenging scenarios such as snow, fog, sun glare, and low contrast environments.
- Provide and deliver a vehicle presence detection system with the following capabilities:
• Accurate vehicle detection under all environmental and lighting conditions, including adverse weather.
• Radar-based technology that is not reliant on visual contrast.
• Live-streaming video monitoring, either integrated into the detection unit or as a separate camera component.
• Detection zones for both stop line presence and advance detection, with a preferred advance detection range of 182 meters (600 feet) or greater.
• Support for traffic data collection, such as vehicle counts, with the ability to access and download data locally, without the need for cloud-based or subscription services.
• Full compatibility with the city’s existing econolite centracs traffic control software.
• Equipment and components suitable for mounting inside a standard traffic cabinet.
• Shelf mounted preferred.
- Technical requirements
• Detection technology: active radar-based detection system
• Intersection support: capable of detecting all approaches of a 4-way intersection
• Advance detection range: minimum of 182 m (600 ft)
• Stop line detection: for both moving and stopped vehicles
• Visual monitoring: integrated or separate IP camera (streaming video)
• Centracs compatibility: full compatibility with econolite centracs software
• Traffic count data: locally stored, downloadable; no subscription or cloud access required
• Cabinet equipment format: shelf-mounted (preferred over rack-mounted)
• Connectivity: ethernet port; capable of wan connection via existing city wireless network
• Cabling: standard 3-wire or cat-5 cabling preferred
• Ingress: protection minimum ip67
• Operating temperature: minimum -34°c to +70°c (lower minimum preferred; high end standard acceptable)
• Compliance standards: NEMA ts2 compliant.
- Contract Period/Term: 1 year
- Questions/Inquires Deadline: September 10, 2025